JBJ Chiller Support

Questions about your JBJ Arctica chiller? Text us for the fastest reply, or start with the chiller questions and answers, the parts compatibility checker and the manuals and guides.

Chiller trouble nearly always sits on the water side, the air side, or in one worn part. Pick what you see below; each card links to the guide, manual, video or part that deals with it.

Fix it now

Start with the screen: a code, or no display at all, narrows it down fastest.

Codes on the display

Arctica DBA, DBE and DBM models. The meaning in quotes is JBJ's wording from the owner's manual (PDF), page 6.

ShowsJBJ saysWhat to check
Hr.1“Abnormal signal of sensor”Damage along the probe wire, or water that has got into its joints.
Lo.1“Overcooling”JBJ says a water reading below -5 °C means the probe has failed or a connection is loose.
E.11“Short circuit”A probe wire that has been pinched or torn.
E.12“Short circuit”A probe wire that has come disconnected.
- - -Blank displayTest the outlet with a lamp, then the fuse: at the back near the cord, or on the side panel of the DBM-250. Fuse guide (PDF)

Seeing F2? It is not in JBJ's manual; our F2 support article covers it.

Light blinking but the compressor is quiet? After power-up the controller waits up to 3 minutes before it starts the compressor. That pause protects it and is not a fault.

  • Running, but the water stays warm

    Rule out flow first: pump on, hoses straight, pre-filter clean. Then dust on the fins and the air around the unit. JBJ's static test shows whether the chiller itself is at fault.

  • No power at all

    If the outlet works, the fuse is the usual suspect. The right one depends on your model and on whether the cord has an on/off switch.

  • New rattle or louder noise

    A steady hum is normal. A fresh rattle is often a loose panel or a dusty, unbalanced fan blade. Unplug it and look before ordering anything.

  • Runs for hours, or clicks on and off

    JBJ's FAQ puts a correctly sized chiller at roughly 15 to 20 minutes of running in each hour. Non-stop running points to flow, dust or an undersized unit; quick on-off cycles usually mean the probe sits in still water.

  • Temperature reading jumps around

    JBJ lists two causes: waste building up in the coil, which a back-flush clears, or a failing probe or controller.

Keep it running

A clean coil and clear fins do more for cooling than any setting on the controller.

  • The care routine

    Monthly checks: grille, airflow, probe position and the parts that wear first.

  • Back-flush the coil

    Twice a year suits most tanks: a bucket, a small pump and white vinegar or citric acid, then two fresh-water rinses.

Set-up

Weak cooling often starts with placement and flow.

  • Home aquarium install

    1/10 to 1/3 HP and Nano models: placement, hoses, flow range by model and the first start.

  • Commercial install

    1/2 to 3 HP: power, plumbing, room space and one chiller serving several tanks.

  • Right size for the job

    An undersized chiller looks broken because it never stops. Check the size before you chase parts.

Parts & manuals

The serial on the back label starts with the month and year it was built, so 0822 means August 2022. Our electrical parts fit chillers made in 2015 or later.

Warranty & returns

The short version; restocking fees and full wording are in our terms.

  • Buy it here and we handle your warranty for you. Order your chiller and parts from JBJChillers.com, then text us the order number, model and serial and we take it from there. Parts, manuals, videos and support for every Arctica are on this site, so there is no need to shop anywhere else.
  • Arctica aquarium and nano chillers carry a 2-year warranty against defects; Commercial chillers (DA series) carry 1 year. Text us the model if you are unsure which you have.
  • Cover runs from the day you bought it, so keep the order email.
  • Damaged in transit: tell us within 24 hours of delivery, keep all the packaging and send photos.
  • Every return needs a return authorization number, requested within 10 days of the invoice date.
  • An electrical part bought for the wrong model year cannot come back. Run the checker first.

Talk to us: start with a text

A text tells us what kind of problem you have, so we can hand it to the person best equipped to fix it. It is the quickest way to an answer.

  1. Step 1: Text us first

    Send the model, the serial from the back label, what the display shows and a photo of the setup. That saves a round of questions.

    Text 916-800-COLD (2653)
  2. Step 2: Texted us and no reply after one working day?Yes, show step 2

    Email us. Put your order number and the same details in the email.

    Email Jbjnanocubes [at] gmail.com
  3. Step 3: Emailed us and still no answer by the next working day?Yes, show step 3

    Call us. Have your order number ready.

    Call 916-800-2653

From the JBJ support files

My Jbj Chiller is showing a F2 error what does this mean?

F2 means the controller is not making good contact in your aquarium chiller. Somehow upon doing the maintenance the controller was moved or lost connection.

Doing a static test to determine Aquarium Chiller Issues

There are many factors that may affect the cooling performance of your JBJ Arctica chiller. In order to determine the cause we recommend the following: • Perform Static Test • Read FAQ s • Contact us for further assistance

FAQ on JBJ Chiller

FAQ s : Q: Why is there no digital display on the controller? A: a. Make sure the power cord is plugged into a working electrical receptacle b. The fuse may be blown; it is located at the rear of the chiller. Q: What size fuse do I need to replace a blown fuse? A: There are two types of fuses used for Aquarium Series Chillers 1. Chillers with a hardwired power cord and external black fuse cap a. DBA-075 – 10 Amp / 250 Volt Ceramic Fuse / Item No: DB-F2-10 b. DBA-150 - 10 Amp / 250 Volt Ceramic Fuse / Item No: DB-F2-10 c. DBE-200 - 15 Amp / 250 Volt Ceramic Fuse / Item No: DB-F2-15 d. DBM-250 - 15 Amp / 250 Volt Ceramic Fuse / Item No: DB-F2-15 2. Chillers with a disconnect power cord which has an ON/OFF switch a. DBA-075 – 10 Amp / 250 Volt Glass Fuse / Item No: DB-F-10 b. DBA-150 - 10 Amp / 250 Volt Glass Fuse / Item No: DB-F-10 c. DBE-200 - 16 Amp / 250 Volt Glass Fuse / Item No: DB-F-16 d. DBM-250 – 16 Amp / 250 Volt Glass Fuse / Item No: DB-F-16