Four numbers tell you which JBJ Arctica chiller your water needs. Fill them in and the answer updates as you type.
Good to know before you pick a size: chiller cooling ratings are measured in ideal conditions: a cool room, open air around the chiller and the right water flow. Real rooms run warmer, and pumps, lights and sunlight all add heat. That is why we recommend choosing one chiller size larger than the result below. A chiller with room to spare runs less often, stays quieter and lasts longer.
Chiller size calculator
Enter your tank size to see your chiller.
How the calculator decides
Your chiller has two jobs. It pulls the water down from room temperature to the temperature you want, and it removes the heat your lights, pumps and heaters keep adding. The calculator adds both up in BTU per hour, the same unit JBJ rates its chillers in:
- Water: gallons x 8.3 lb per gallon x degrees to drop, spread over 24 hours.
- Equipment: every watt turns into 3.413 BTU per hour of heat.
- Margin: the total x 1.25, so the chiller cycles on and off instead of running flat out. Cold plunge tubs get x 1.5, because the water sits far below room temperature.
It then picks the smallest JBJ Arctica chiller that can remove that much heat and is rated for that many gallons, so it never sends you to a chiller that is too small.
Measuring your water
Use inside measurements in inches: Length x Width x Height / 231 = gallons. A 48 x 24 x 24 tank holds about 120 gallons. Then add everything else the water flows through: sump, refugium, frag tank, reservoir. The chiller cools all of it.
JBJ Arctica chillers at a glance
| Chiller | Heat it removes (BTU/hr) | Gallons | Pump flow (GPH) |
| Nano E-Chiller 10G (DBI-010) | thermoelectric, about 9°F below room | up to 10 | pump included |
| Nano E-Chiller 20G (DBI-020) | thermoelectric, about 9°F below room | up to 20 | pump included |
| 1/15 HP Mini Nano | 800 | up to 52 | 132-528 |
| 1/10 HP (DBA-075) | 1,200 | up to 104 | 240-960 |
| 1/5 HP (DBA-150) | 2,400 | up to 144 | 480-1,320 |
| 1/4 HP (DBE-200) | 3,000 | up to 208 | 480-1,920 |
| 1/3 HP (DBM-250) | 4,000 | up to 272 | 480-1,920 |
| 1/2 HP Commercial 115V (DA-500) | 6,000 | up to 400 | 474-792 |
| 1/2 HP Commercial 230V (DA-500-230V) | 6,000 | up to 528 | 474-792 |
| 1 HP Commercial (DA-1000) | 12,000 | up to 640 | 636-954 |
| 1-1/2 HP Commercial (DA-1500) | 18,000 | up to 960 | 954-1,428 |
| 2 HP Commercial (DA-2000) | 24,000 | up to 1,280 | 1,266-1,902 |
| 3 HP Commercial (DA-3000) | 36,000 | up to 1,920 | 1,902-2,856 |
| 5 HP Commercial (DA-5000) | 60,000 | up to 3,200 | discontinued |
Before you buy
- Flow: your pump must push water through the chiller inside the flow range above. Outside that range the chiller cools less and works harder.
- Pump head: the flow printed on a pump's box is measured with no lift and no plumbing. Every foot the pump has to push water up, and every bit of tubing, elbow, valve and the chiller coil itself, pushes back. That resistance is called head, and the more head, the less water the pump moves. Before you pick a pump, add up your head: the height from the pump to the top of the tank, plus about 1 ft for every 10 ft of tubing, about 1 ft for each elbow or valve, and a few feet for the chiller and any filter or UV in the same line. Then find the pump's flow chart (its flow curve) and read the flow at that head. That number, not the box rating, must land inside the chiller's flow range in the table above. Aim for the middle of the range so a dirty filter or sock does not drop you below it.
- Pump or powerhead? A powerhead is built to stir water inside the tank. It moves a lot of water at almost no head, so most powerheads cannot push enough water through a chiller and back up to the tank. Use a return pump in the sump, an in-line pump, or a submersible pump whose flow chart shows enough flow at your head. See JBJ aquarium pumps.
- Power: the 1/2 HP comes in 115V and 230V. The 1 HP to 3 HP commercial models are 230V. The 5 HP (DA-5000) is discontinued.
- Air: the heat a chiller removes goes into the room. Give its vents open air. In a closed cabinet it ends up cooling its own exhaust.
Already own a JBJ chiller and need a part? See JBJ Arctica replacement parts.